  • 矩阵电离室剂量仪(1).jpg

Matrix ionization chamber dose meter

The entire matrix dosimeter consists of 1024 atmospheric flat plate ionization chambers,(32 columns x 32 rows). Sensitive volume of ionization chamber: 0.08cc. Center spacing of ionization chamber: 8mm. Each ionization chamber has a separate electrometer channel. Electrometer measuring range: (current). Dose range:(0.02Gy to 20Gy). Minimum sampling time: 20ms. Working high pressure: 300V. Non-linearity: ≤ ± 0.2%. Repeatability of dose measurement: ≤ 0.1%. Stability: ≤ 0.1%. With temperature \pressure sensor automatic temperature pressure correction. The equipped angle sensor can compare the angle measurement data with the corresponding The dose data are correlated, so that the real dose data of different positions can be easily obtained.

Classification:

Radiation Medicine

Key recommendations

Product accessories:

Picture Name

24-hour free hotline

Product Description

The entire matrix dosimeter consists of 1024 atmospheric flat plate ionization chambers,(32 columns x 32 rows).

Sensitive volume of ionization chamber: 0.08cc center spacing of ionization chamber: 8mm

Separate electrometer channels for each ionization chamber

Electrometer measuring range: (current)

Detector effective measurement area: 30x30c㎡

Dose range:(0.02 Gy ~ 20 Gy)

Minimum sampling time: 20ms

Working high pressure: 300V

Non-linearity: ≤ ± 0.2%

Repeatability of dose measurement: ≤ 0.1%

Charge resolution: 0.5pC

Stability: ≤ 0.1%

With temperature \pressure sensor automatic temperature pressure correction,The equipped angle sensor can associate the angle measurement data with the corresponding dose data in real time, and can conveniently obtain the real dose data at different positions.

Dose meter and PC using USB interface standard, communication protocol: TCP/IP

Power supply voltage range: 220V ~ 50Hz

Dimensions: 550mm (length) × 410mm (width) × 45mm (thickness)

Software features:

Dose Verification and Quality Assurance Application Software for the Whole Process of Intensity-modulated Therapy

Real-time two-dimensional intensity distribution measurement of irradiation therapy system

With one-dimensional, two-dimensional, and three-dimensional data display function: curve, equal dose contour, two-dimensional/three-dimensional dose distribution map